How much condensate does your station produce?

Water balance between the intake and the cooler or dryer outlet, on the same dry-air basis.

Your inputs

Example data – these are not your operating figures. Adjust them before calculating.

Result

Enter your inputs and run the calculation. See the result immediately, without registering or providing an email address.

How we calculate

Method: ṁdry = Qintake(patm − pv)/(RdryTintake). Mixing ratio x = 0.62198 pv/(p − pv). Separated water = ṁdry × max(xinlet − xoutlet, 0). 1 kg of condensate ≈ 1 litre.

Assumptions and limitations: No addition of moisture or oil. A negative balance means the outlet air is not saturated; no water is formed. The dryer outlet represents total separation from the intake, not an addition to the cooler result already calculated. Below zero, ice rather than liquid condensate is assumed.

Method references
  • Vaisala: Humidity Conversion Formulas B210973-F, equation 6 and table 1 – saturated vapour pressure over water and ice.

Method version 1.0. Standard references verified in the ISO catalogue; the physical balances are not calculations prescribed by ISO. Before final design, we will verify actual operating and catalogue data.