20+ service techniciansThe largest compressor rental fleet in Czechia and SlovakiaImmediate response, 24/79 branches in Czechia and Slovakia

Compressors PEMA

Energy efficiency comes first

Oil-injected and oil-free compressors for industry. We help you choose the right range, design the compressor room and provide service.

PEMA compressors in use

Component quality matters.

A reliable compressor starts on the inside. PEMA compressors use components from proven manufacturers.

  • Siemens
  • ABB
  • Donaldson
  • Inovance
  • MANN-FILTER
  • Schneider Electric
  • SKF

The brands used depend on the compressor range and configuration. We will specify the exact components in the quote.

Oil-injected compressors

For standard industrial air systems and everyday production. GTS and GTX use two-stage compression. GSX Tower+ is designed for a small footprint, with a single-stage screw element, integrated dryer and filtration. GTS operates at fixed speed; GTX and GSX Tower+ use variable-speed control.

PEMA GTS / GTXTwo-stage screw compressors

PEMA GTS 30 compressor
Power
22–200 kW
Flow rate
2,5–40,5 m³/min

GTS and GTX are oil-injected screw compressors for industrial production. Air is compressed in two stages, with oil cooling between stages. This reduces the work required for compression and helps maintain lower operating temperatures.

GTS operates at fixed speed, switching between load and unload. GTX uses a frequency inverter to adjust speed to the current air demand.

Both ranges have direct drive and are prepared for an external heat exchanger. An integrated exchanger for waste heat recovery is also available to order. The choice between GTS and GTX is determined mainly by demand patterns during the shift.

PEMA GSX Tower+Compact compressors with integrated dryer and filtration

PEMA GSX 22 Tower+ compressor
Power
11–75 kW
Flow rate
1,94–16,8 m³/min
Working pressure
7–10 bar

GSX Tower+ is an oil-injected screw range designed for compact dimensions. Its single-stage screw element, integrated drying unit and filtration combine compressed air generation and treatment in one machine, saving space in the compressor room.

The Siemens controller works with an Inovance frequency inverter. A permanent-magnet synchronous motor and variable-speed control adapt air production to current demand.

While GTS and GTX use two-stage compression, GSX Tower+ prioritises a small footprint. It therefore combines a single-stage element with integrated drying and filtration. It is a suitable choice where a compact overall installation is the deciding factor.

Oil-free compressors

For processes requiring oil-free compression. ZRX, SCT and ZDX differ in compression principle and power range. Oil-free compression alone does not address moisture or contaminants drawn in with intake air, so suitable drying and filtration are also part of the design.

PEMA ZRXWater-injected

PEMA ZRX 90 compressor
Power
7,5–132 kW
Flow rate
1,1–23,3 m³/min

In the ZRX range, water seals and cools the compression chamber instead of oil. It removes the heat generated during compression without the need to inject oil into the compression chamber.

ZRX uses variable-speed control through a frequency inverter. It is a solution for industrial processes requiring oil-free compression and varying air demand. We design downstream drying and filtration to meet production requirements.

PEMA ZRX series details

PEMA SCTScroll compressors

PEMA SCT 22 compressor
Power
1,5–45 kW
Flow rate
0,12–4,8 m³/min

SCT uses scroll compression with no oil in the compression chamber. The range starts at 1.5 kW, offering solutions for lower compressed air demand too.

We consider this range for sensitive process applications where oil-free compression and noise levels matter. We select the version and control method according to the model and application requirements; we do not assume one control method across the whole range.

PEMA ZDXDry-running two-stage compressors

PEMA ZDX 75 compressor
PEMA ZDX 75 compressor
Power
55–355 kW
Flow rate
7,8–72 m³/min

ZDX is an oil-free screw range for high industrial air demand. It uses a GHH RAND two-stage dry-running compression element that compresses air without injecting oil into the compression chamber.

Variable-speed control through a frequency inverter adapts output to demand within the machine's operating range. The design also considers cooling, air treatment and coordination with other compressors in the station.

The stated values cover entire ranges, not performance at one common pressure. GTS/GTX share a combined range. We will confirm the specific model and its flow at the required pressure in the technical quote.

BUILT FOR INDUSTRY

HEAVY
DUTYBuilt for long service.

Durability, serviceability and lifespan are not extras. They are part of the compressor's design.

We go against the trend.

Smaller at any cost?
That is not our approach.

A compact machine saves space. But saving a few centimetres should not mean poorer cooling, cramped maintenance access or a less robust structure.

We also reject the idea of using equipment until it fails and then throwing it away. We prefer designs that can be maintained, repaired and operated for the long term.

No compromises on lifespan.
Yes to solid engineering.

Robust construction

We design the rigid frame and robust enclosure for machine stability and repeated handling. The compressor must withstand not only air production, but also transport and installation.

Service without unnecessary obstacles

Filters, oil and other routine maintenance points must be easy to access. We consider serviceability during design, not only when something needs replacing.

Adequately sized coolers

Cooling must not be sacrificed to reduce enclosure size. We design cooler size and airflow for the thermal load and more demanding operating conditions.

Steel piping instead of hoses

Where the design permits, we prefer steel piping to hoses. The aim is to reduce damage risk and the need for regular replacement.

Larger airend, lower speed

We size the screw element to deliver the required flow at lower operating speeds. This addresses efficiency as well as bearing loads and lifespan.

Bearings that can be maintained

For motors with regreasable bearings, regular lubrication is part of maintenance. Access to lubrication points and adherence to manufacturer intervals help make the most of bearing life.

Heavy Duty describes our design approach, not a separate certification. Specific design solutions vary by range and machine version; operating limits and maintenance are defined by the technical documentation.

Efficient operation starts with the right design

Energy consumption is not determined by motor size alone. Working pressure, demand patterns during the shift and control of the entire compressor room all matter. Two-stage compression and variable-speed control address different aspects; we always assess their benefits against actual operating conditions.

Waste heat recovery

GTS and GTX are prepared for an external heat exchanger and can also be ordered with an integrated exchanger. Heat generated during compression can therefore be used to heat water. Whether the solution makes sense depends on how much heat your operation can regularly use.

Controls for industrial operation

GSX Tower+ has a Siemens controller and Inovance frequency inverter. Other ranges use Siemens or MAM controllers, depending on the version. Modbus RTU communication is available for connection to a supervisory system; we check integration options for the selected model.

Two PEMA GSX 22 Tower+ compressors in a compressor room
Compact installation with PEMA GSX Tower+ compressors

We verify efficiency in practice

We work with VSB – Technical University of Ostrava and the ENET Centre on independent compressor performance and efficiency testing according to ISO 1217.

Measurements help verify flow and energy consumption under defined conditions. When comparing quotes, we therefore use the specific machine and operating point, not just a general label such as “energy-efficient compressor”.

VSB – Technical University of Ostrava, ENET Centre
Facilities of the Centre for Energy and Environmental TechnologiesPEMA compressor in a test installation
PEMA LEASE · OPERATING LEASE

COMPRESSOR ROOM
ON AN OPERATING LEASE

You handle production. We handle the compressor.

You do not have to look after the compressor on your own. With PEMA LEASE, we take on the agreed care of the supplied machine. You get a clear budget and more time for your work.

  • Scheduled servicing and routine repairs included in the monthly payment
  • Operational support according to the selected option
  • One partner to call
How operating leasing works
Completed PEMA compressor roomCompressor transport and handling at PEMA facilitiesREDBOX outdoor compressor stationAtlas Copco compressor delivery by the PEMA team

OUR REFERENCES
SPEAK FOR THEMSELVES.

Real machines. Real operations. See where our work helps keep production running every day.

See for yourself

Not sure which range to choose?

Describe your operation. We will recommend a compressor and the air treatment you need.

Contacts and branches

PEMA compressors in use

ContactEnquiry