Kompresory PEMA s.r.o.
EN
Menu
20+ service techniciansThe largest compressor rental fleet in Czechia and SlovakiaImmediate response, 24/79 branches in Czechia and Slovakia
Articles and practical experience

Compact air flowmeter without a straight inlet section

The new compact air flowmeter from German manufacturer CS Instruments GmbH has an interesting design.

The new compact air flowmeter from CS Instruments GmbH has an interesting design. Conventional calorimetric flowmeters require a straight calming section of 10–30 × DN (pipe diameter) for accurate measurement. Thanks to its diffuser, this meter can be installed without that section. Its installation length is only 135 mm. It is available in sizes from ¼ to 2 inches and, depending on internal diameter, with a measuring range of 3.6–1,195 m3/h (up to 1,450 m3/h in the max-flow version). It is suitable for air and common industrial gases (Ar, CO2, N2, O2, N2O).

The standard measurement accuracy is 1.5%, a very good figure. Unlike flowmeters with a straight calming section, it is also available with a lower accuracy of 6%, suitable where only approximate consumption measurements are needed, for example for individual machines.

A version with integrated pressure measurement is also available.

The device retains all parameter settings and communication outputs: 4–20 mA analogue, pulse output and RS485 Modbus RTU. Its price makes it an attractive option for monitoring consumption in individual production areas or the central compressor room.

Compact air flowmeter without a straight inlet section – PEMA photo
ContactEnquiry