Will water condense or freeze in the pipework?

Compare the lowest temperature with the dew point at the actual pressure at that location.

Your inputs

Example data – these are not your operating figures. Adjust them before calculating.

Result

Enter your inputs and run the calculation. See the result immediately, without registering or providing an email address.

How we calculate

Method: The mole fraction of water remains constant as pressure changes: pv₂ = psat(Tdp₁) × p₂/p₁. Inverting the Vaisala relation gives the new dew point and atmospheric dew point. Below 0 °C, we calculate the frost point over ice.

Assumptions and limitations: Valid for an ideal gas without added water and before condensation. Does not include entrained liquid water or local cold spots. A negative dew point in this tool means a frost point; check the instrument's convention.

Method references
  • Vaisala: Humidity Conversion Formulas B210973-F, equation 6 and table 1 – saturated vapour pressure over water and ice.

Method version 1.0. Standard references verified in the ISO catalogue; the physical balances are not calculations prescribed by ISO. Before final design, we will verify actual operating and catalogue data.