How long does the receiver take to fill or empty?

Find the time needed for a pressure change from the net balance of supply and demand.

Your inputs

Example data – these are not your operating figures. Adjust them before calculating.

Result

Enter your inputs and run the calculation. See the result immediately, without registering or providing an email address.

How we calculate

Method: t = V × (pfinal − pinitial) / [pref × (Qsupply − Qdemand)] × Tref/Tvessel. Constant flows, isothermal ideal gas.

Assumptions and limitations: Short events are often non-isothermal. Delivery may change with pressure and control. This is neither a switching-frequency calculation nor a safety design.

Method references
  • CAGI Compressed Air & Gas Handbook, chapter 4, 2021 – system design, storage and pressure losses.

Method version 1.0. Standard references verified in the ISO catalogue; the physical balances are not calculations prescribed by ISO. Before final design, we will verify actual operating and catalogue data.